Tubing Detection Fire Suppression System Specification

  • Mounting Type
  • Bracket mounting / clamp inside cabinet
  • Working Temperature
  • -30C to +60C
  • Fire Extinguisher Type
  • Clean Agent (Novec 1230/FM200/CO2 depending on model)
  • Connectivity Type
  • Standalone (no external communication)
  • Energy Efficiency Rating
  • Not applicable / N/A
  • Technology
  • Pneumatic Tubing Detection and Release
  • Features
  • Automatic activation, rapid suppression, minimal residue, easy installation, zero electricity required
  • Control Type
  • Automatic (self-actuating)
  • Voltage
  • Not required for activation (manual system)
  • Installation Type
  • Wall or surface mounted inside equipment enclosure
  • Fire Class
  • Class A, B, C
  • Coating Type
  • Corrosion-resistant epoxy paint on cylinder
  • Shape
  • Cylindrical cylinder
  • Operating Pressure
  • 15-18 bar
  • Coverage Area
  • Covers up to 1.5 to 4 cubic meters depending on system size
  • Application
  • Direct and automatic fire detection and suppression in electrical panels, server racks, and enclosed equipment areas
  • Max Flow Rate
  • Dependent on cylinder capacity (generally 2-5 kg/sec for agent discharge)
  • Diameter
  • Typically 8 mm for detection tubing
  • Capacity
  • Typically 1 kg, 2 kg, or as required
  • Pressure
  • Stored pressure, approx. 15-18 bar
  • Noise Level
  • Silent or minimal during detection, audible on agent discharge
  • Tubing Material
  • Special flame-retardant polymer
  • System Reset Time
  • Requires tube/cylinder replacement/refill after activation
  • Cylinder Material
  • Seamless steel or aluminum
  • Maintenance
  • Annual inspection recommended
  • Suppression Gas Release
  • Triggered directly where tubing ruptures
  • Weight
  • Varies by cylinder (approx. 2-5 kg total system weight)
  • Environmental Impact
  • Clean agent gases, ozone-friendly
  • Response Time
  • Instantaneous (on heat/temperature trigger)
  • Detection Method
  • Heat-sensitive polymer tubing bursts at fire point
  • Refillable
  • Yes, system is refillable and rechargeable
 

Tubing Detection Fire Suppression System Trade Information

  • Minimum Order Quantity
  • 1 Unit
  • Payment Terms
  • Cash in Advance (CID)
  • Supply Ability
  • 100 Units Per Month
  • Delivery Time
  • 7 Days
  • Main Domestic Market
  • All India
 

About Tubing Detection Fire Suppression System



Unlock unrivaled protection with our Famed Tubing Detection Fire Suppression System, designed for opulent safety in scarce, critical enclosures. The system employs heat-sensitive polymer tubing that bursts instantly upon fire detection, releasing a clean agent gas directly at the ignition point. With seamless steel or aluminum refillable cylinders and corrosion-resistant coating, this legendary solution promises minimum residue and maximum performance. Personalise safety in server racks, electrical panels, and enclosed equipment with silent operation, effortless installation, and annual low-maintenance - all in a compact, robust package.

Versatile Use and Application Areas

The Tubing Detection Fire Suppression System is widely used by retailers, service providers, suppliers, traders, and wholesalers across India. Ideal for electrical panels, server racks, and various enclosed equipment spaces, this system guarantees secure, automatic fire detection and suppression. Its direct-application tubing and automatic release make it the preferred choice for safeguarding valuable assets in environments where access is limited and protection is paramount.


Packaging, Dispatch, and Supply Details

Each unit is meticulously packaged for safe transit, ensuring the system arrives in pristine condition. Quotes and pricing are tailored to project specifications. Standard order quantities are quickly dispatched with reliable freight services, guaranteeing timely delivery nationwide. Our supply ability accommodates large and urgent requirements. Samples are available upon quotation request, allowing for practical evaluation before deployment within your critical systems.


FAQ's of Tubing Detection Fire Suppression System:


Q: How does the Tubing Detection Fire Suppression System operate?

A: The system utilizes heat-sensitive polymer tubing that automatically ruptures at the fire source, directly releasing the suppression gas through the rupture point for rapid extinguishing.

Q: What type of fires can this suppression system combat?

A: It is engineered to tackle Class A, B, and C fires within enclosed equipment like server racks and electrical panels using clean agent gases, ensuring minimal residue and no damage to sensitive equipment.

Q: Where can this system be installed?

A: The system is designed for wall or surface mounting inside cabinets, electrical panels, enclosed server racks, and various equipment enclosures, providing automatic fire defense precisely where required.

Q: When should maintenance be performed on the system?

A: Annual inspections are recommended to ensure optimal performance. After activation, the tubing and cylinder must be replaced or refilled before returning to service.

Q: What are the benefits of using this fire suppression system?

A: Benefits include rapid, localized suppression, silent operation before discharge, zero electricity requirement, minimal clean-up, and ozone-friendly clean agent usage, offering seamless safety in critical infrastructure.

Q: How can I obtain a quotation or a sample of the system?

A: You may request a quote or sample through the supplier, retailer, or distributor in India. Samples and project-specific quotations are provided upon inquiry to meet your unique requirements.

Tell us about your requirement
product

Price:

Quantity
Select Unit

  • 50
  • 100
  • 200
  • 250
  • 500
  • 1000+
Additional detail
Mobile number

Email

More Products in Fire Fighting System Category

Fire Suppression System

Fire Suppression System

Minimum Order Quantity : 1 Unit

Coverage Area : Customizable as per site requirements

Features : Rapid suppression, residuefree, environmentfriendly

Technology : Clean agent (Novec 1230) fire suppression

Capacity : Varies by cylinder, commonly 40L, 80L, 120L, up to 300L

Connectivity Type : Wired to detection and control panel

Kitchen Fire System

Kitchen Fire System

Minimum Order Quantity : 1 Unit

Coverage Area : Depends on nozzle arrangement; up to 1020 sq. meters

Features : Automatic detection & activation, Quick response, Nontoxic suppressant, Minimal residue

Technology : Wet Chemical Suppression System

Capacity : 912 liters

Connectivity Type : Wired; Control Panel Connected